Resultados 1 - 20 de 871
Filtrar
1.
Clin Lab ; 70(5)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38747905

RESUMO

BACKGROUND: Cold agglutinins (CAs) in blood samples can cause a reversible agglutination of red blood cell (RBC) which result in an incorrect complete blood count (CBC). So, it is important to explore new simple and feasible treatment conditions for clinical work. METHODS: The CAs group included 32 samples with CAs. The parameters of CBC at room temperature or after prewarming at 37°C or 41°C for different time periods were compared. The consistency and correlation of those parameters were analyzed. The morphology of erythrocytes in the CAs group was observed manually. The control group included 45 samples without CAs and prewarmed at 37°C or 41°C for different time periods. The differences were also analyzed. RESULTS: CAs have a significant effect on CBC. After prewarming at 37°C or 41°C the interferences are all corrected. Consider prewarming at 37°C for 120 minutes as the standard procedure. The consistency and correlation analysis showed there was no statistical difference between the results of each subgroup and standard group, except the MCHC of group 41°C 10 minutes. The correlation of parameters between all subgroups and the standard group is satisfied. Microscopic examination showed no RBC aggregation or fragmentation after prewarming at 41°C or 37°C. According to the maximum bias requirements for expert performance in Validation, Verification, and Quality Assurance of Automated Hematology Analyzers, 2nd Edition (CLSI H26-A2), the differences in overall results in control group are negligible. CONCLUSIONS: The 41°C 2 minutes prewarming method is a rapid and effective way for treating samples with CAs. It is an efficient way to obtain more reliable CBC results, without specific instruments.


Assuntos
Crioglobulinas , Eritrócitos , Humanos , Crioglobulinas/análise , Contagem de Células Sanguíneas/métodos , Reprodutibilidade dos Testes , Temperatura , Fatores de Tempo , Agregação Eritrocítica , Aglutinação
2.
Sci Rep ; 14(1): 10841, 2024 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-38736010

RESUMO

Optimizing early breast cancer (BC) detection requires effective risk assessment tools. This retrospective study from Brazil showcases the efficacy of machine learning in discerning complex patterns within routine blood tests, presenting a globally accessible and cost-effective approach for risk evaluation. We analyzed complete blood count (CBC) tests from 396,848 women aged 40-70, who underwent breast imaging or biopsies within six months after their CBC test. Of these, 2861 (0.72%) were identified as cases: 1882 with BC confirmed by anatomopathological tests, and 979 with highly suspicious imaging (BI-RADS 5). The remaining 393,987 participants (99.28%), with BI-RADS 1 or 2 results, were classified as controls. The database was divided into modeling (including training and validation) and testing sets based on diagnostic certainty. The testing set comprised cases confirmed by anatomopathology and controls cancer-free for 4.5-6.5 years post-CBC. Our ridge regression model, incorporating neutrophil-lymphocyte ratio, red blood cells, and age, achieved an AUC of 0.64 (95% CI 0.64-0.65). We also demonstrate that these results are slightly better than those from a boosting machine learning model, LightGBM, plus having the benefit of being fully interpretable. Using the probabilistic output from this model, we divided the study population into four risk groups: high, moderate, average, and low risk, which obtained relative ratios of BC of 1.99, 1.32, 1.02, and 0.42, respectively. The aim of this stratification was to streamline prioritization, potentially improving the early detection of breast cancer, particularly in resource-limited environments. As a risk stratification tool, this model offers the potential for personalized breast cancer screening by prioritizing women based on their individual risk, thereby indicating a shift from a broad population strategy.


Assuntos
Neoplasias da Mama , Aprendizado de Máquina , Humanos , Neoplasias da Mama/sangue , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto , Idoso , Contagem de Células Sanguíneas/métodos , Medição de Risco/métodos , Detecção Precoce de Câncer/métodos , Brasil/epidemiologia
3.
J Clin Apher ; 39(3): e22114, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38708583

RESUMO

BACKGROUND: Stem cell apheresis in the context of autologous stem cell transplantation requires an accurate cluster of differentiantion 34 (CD34+) count determined by flow cytometry as the current gold standard. Since flow cytometry is a personnel and time-intensive diagnostic tool, automated stem cell enumeration may provide a promising alternative. Hence, this study aimed to compare automated hematopoietic progenitor enumeration carried out on a Sysmex XN-20 module compared with conventional flow cytometric measurements. METHODS: One hundred forty-three blood samples from 41 patients were included in this study. Correlation between the two methods was calculated over all samples, depending on leukocyte count and diagnosis. RESULTS: Overall, we found a high degree of correlation (r = 0.884). Furthermore, correlation was not impaired by elevated leukocyte counts (>10 000/µL, r = 0.860 vs <10 000/µL, r = 0.849; >20 000/µL, r = 0.843 vs <20 000/µL, r = 0.875). However, correlation was significantly impaired in patients with multiple myeloma (multiple myeloma r = 0.840 vs nonmyeloma r = 0.934). SUMMARY: Stem cell measurement carried out on the Sysmex XN-20 module provides a significant correlation with flow cytometry and might be implemented in clinical practice. In clinical decision-making, there was discrepancy of under 15% of cases. In multiple myeloma patients, XN-20 should be used with caution.


Assuntos
Antígenos CD34 , Citometria de Fluxo , Células-Tronco Hematopoéticas , Humanos , Citometria de Fluxo/métodos , Antígenos CD34/análise , Antígenos CD34/sangue , Células-Tronco Hematopoéticas/citologia , Mieloma Múltiplo/sangue , Mieloma Múltiplo/diagnóstico , Masculino , Feminino , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/instrumentação , Pessoa de Meia-Idade , Contagem de Leucócitos , Adulto
4.
J Clin Lab Anal ; 38(4): e25017, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38396348

RESUMO

BACKGROUND: Three-part differential (3PD) haematology analysers offer a quick, easy-to-use and economical way to acquire important information about a patient's physiology. In this study, we evaluated a new 3PD analyser, the Sysmex XQ-320, investigated its comparability with its predecessor (Sysmex XP-300) and the five-part differential analyser Sysmex XN-9000, and explored its flagging potential. METHODS: Analytical performance studies were conducted for repeatability, within-laboratory precision, between-day precision, carry-over and linearity with fresh blood and QC material. Method comparison was performed in 493 samples comparing XQ-320 with XP-300, using the XN-9000 as the gold standard. RESULTS: The XQ-320 excelled manufacturer's specifications in the analytical performance studies, except for MXD in within-laboratory and between-day precisions using the QC material level 1. The XQ-320 showed correlation values greater than 0.94 with XN-9000 for the majority of the 20 reportable parameters (MXD# 0.891, MXD% 0.898 and MCHC 0.849). Improvements over the XP-300 were observed in WBC in the leucocytopenic range (bias -0.038 vs. -0.097) and PLT (bias 2.568 vs. -7.877, intercept 3.880 vs. -8.845). Concordance between XQ-320 and XP-300 was 91.9% for the WBC histogram abnormal distribution flag and 95.3% for the PLT flag. Patterns of increased neutrophils and decreased mixed cells on the XQ-320 were observed in samples that raised a flag on XN-9000. CONCLUSION: The XQ-320 showed excellent analytical performance, and very good to excellent correlation with XN-9000 with improvements over XP-300. Flagging combined with parameter patterns identified additional suspected abnormal samples, thus making the XQ-320 an excellent solution for laboratories utilising 3PD analysers.


Assuntos
Hematologia , Humanos , Laboratórios , Nonoxinol , Contagem de Células Sanguíneas/métodos , Reprodutibilidade dos Testes
5.
Clin Lab ; 70(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38345977

RESUMO

BACKGROUND: The benchtop ADVIA 560 AL hematology analyzer (Siemens Healthineers Tarrytown, NY, USA) offers a small footprint and ease of operation making it suitable for satellite laboratories and intensive care units. A verification study of this analyzer was performed. METHODS: Between- and intra-run precision, carry-over, linearity, and throughput were evaluated on the ADVIA 560 AL. Accuracy was assessed on 94 patient samples by comparing the results obtained on the ADVIA 560 AL to the results on the reference Sysmex XN1000 analyzer (Sysmex Corporation, Kobe, Japan). RESULTS: The ADVIA 560 AL showed acceptable imprecision on control material and minimal bias in comparison to the XN 1000 on patient samples with a throughput of 60 samples per hour. The percentage carryover was not significant and the linearity was within acceptable limits. CONCLUSIONS: The ADVIA 560 AL bench-top analyzer is suitable for acute care centers and satellite laboratories owing to its small footprint, ease of use, and reproducible and accurate results.


Assuntos
Hematologia , Humanos , Contagem de Células Sanguíneas/métodos , Reprodutibilidade dos Testes , Hematologia/métodos , Laboratórios , Japão , Contagem de Leucócitos
6.
Int J Lab Hematol ; 46(3): 466-473, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38263481

RESUMO

INTRODUCTION: Cell population data (CPD) parameters may be putative biomarkers for the screening of various diseases including some infections and myelodysplastic syndrome. This study aimed to establish the age- and sex-specific reference intervals (RIs) for the CPD parameters in the Korean population. METHODS: The reference population for the RIs of CPD parameters comprised 124 856 subjects aged 20-99 years. CPD parameters were obtained from Sysmex XN-2000 (Kobe, Japan) datasets from 17 health promotion centers in 13 South Korean cities. We determined significant partitions for age and sex, and calculated RIs according to Clinical and Laboratory Standards Institute C28-A3 guidelines. RESULTS: The side scattered light intensity in the neutrophil area and the lymphocyte area did not require sex-related partitioning except in those over the age of 50, among whom the lower limit (LL) and upper limit (UL) were lower in females. However, the side scattered light distribution width in the lymphocyte area required age- and sex-related partitioning, in which LL and UL were higher in females. The LL and UL of the fluorescent light distribution width were higher in males in the neutrophil area and higher in females in the lymphocyte area, but age-related partitioning was not required. The forward scattered light intensity in the neutrophil area, lymphocyte area, and monocyte area did not require age-related partitioning in males. CONCLUSION: This study has determined comprehensive age- and sex-specific RIs for CPD parameters, which could help to prove the clinical significance of these parameters in the Sysmex XN-2000.


Assuntos
Neutrófilos , Humanos , Masculino , Feminino , Idoso , República da Coreia , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Valores de Referência , Contagem de Células Sanguíneas/instrumentação , Contagem de Células Sanguíneas/normas , Contagem de Células Sanguíneas/métodos , Fatores Etários , Adulto Jovem , Neutrófilos/citologia , Envelhecimento
7.
Transfus Med ; 34(1): 30-38, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38193379

RESUMO

OBJECTIVES: Our objective was to compare the measurement of residual white blood cell (rWBC) and residual red blood cell (rRBC) counts in blood products using the XN Blood Bank mode and the laboratory standard operating procedures for manual counts. In addition, to compare the whole blood complete blood count (CBC) values of blood donors and the quality of blood products using the Sysmex XN analyser versus the XS-1000i analyser. MATERIALS AND METHODS: For blood donors, 190 samples from blood or apheresis donors were analysed on both the Sysmex XS-1000i and XN-1000 analysers and the mean values of six CBC parameters were compared: the white blood cell count (WBC), the red blood cell count (RBC), haemoglobin (HGB), haematocrit (HCT), the mean corpuscular volume (MCV), the platelet count (PLT). For blood products, 164 samples were collected: 13 Plasma products - whole blood, 9 Plasma products - apheresis, 36 RBC concentrates - whole blood, 30 PLT concentrates - buffy coats, 36 PLT concentrates - buffy coats - pooled and 55 PLT concentrates - apheresis. RESULTS: All CBC parameters of the blood donors tested showed similar performance, with excellent correlation coefficients (r) ranging from 0.821 to 0.995. The majority of the blood products did not have a quantifiable number of residual cells, meaning the number of rWBC and rRBC, if present, was below the limit of quantitation (LoQ) of the different methods. rWBC were detected by Blood Bank mode in Plasma products - whole blood with a mean rWBC of 0.012 × 109 /L and in PLT concentrates - buffy coats with a mean rWBC of 0.19 × 109 /L. The correlation coefficient in both analysers for all three parameters (HGB, HCT, RBC) in RBC concentrates - whole blood was excellent, ranging from 0.95 to 0.99. For platelet count, r ranged from 0.98 to 0.99. CONCLUSION: The XN-Series analyser, equipped with a Blood Bank mode, demonstrated reliable performance when used for blood donor evaluation, rWBC enumeration and measurement of end blood products.


Assuntos
Bancos de Sangue , Doadores de Sangue , Humanos , Contagem de Células Sanguíneas/métodos , Contagem de Plaquetas , Eritrócitos
8.
J Equine Vet Sci ; 132: 104984, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38081332

RESUMO

Asinina de Miranda is a protected donkey sub-species from the Mirandês plateau in northeastern of Portugal. Donkeys are animals that have substantially lost their place as working animals in modern society, this had led to a decrease in their population numbers. A need to preserve native species has led to the foundation of organizations like Associação para o Estudo e Proteção do Gado Asinino (AEPGA) and the development of studies regarding breed welfare, such as hematology. The IDEXX ProCyte Dx is a veterinary hematology analyzer validated for several species, but not for donkeys. The aim of this study was to validate the ProCyte Dx for Asinina de Miranda donkeys. The validation requires a controlled study of precision, carryover, linearity and comparison between the equipment and the manually obtained values for the leukocyte differential count and hematocrit. Results indicated coefficient of variation was good (below 5 %) for both the intra-assay and the inter-assay precision, except for basophils. Carryover was 0 % for all the parameters except platelets (5.88 %). Linearity showed a very high Pearson correlation coefficient, above 0.99, for erythrocytes, hematocrit, hemoglobin, leucocytes, neutrophils, lymphocytes, monocytes, eosinophils, platelets and plateletcrit. Comparison demonstrated excellent agreement for hematocrit (rs=0.96) and good Spearman rank correlation for neutrophils (rs=0.84) and lymphocytes (rs=0.90). Accuracy for total leukocyte count and platelets could not be determined. In conclusion, the ProCyte Dx seems appropriate to be used in Asinina de Miranda hematology.


Assuntos
Equidae , Hematologia , Animais , Contagem de Células Sanguíneas/métodos , Contagem de Células Sanguíneas/veterinária , Reprodutibilidade dos Testes , Contagem de Leucócitos/veterinária , Hematologia/métodos
9.
Int J Lab Hematol ; 46(1): 63-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37731006

RESUMO

INTRODUCTION: The Atellica Hema (Siemens Healthineers, Tarrytown, NY, USA) is a new generation multi-parameter analyzer for full blood count, 6-part differential and reticulocyte testing by impedance variation and fluorescence flow cytometry. In this study, we verified the whole blood and limited body fluid modes of the Atellica Hema 580. METHODS: We evaluated precision, linearity, carry-over, throughput and performed a method comparison to assess the performance of the Atellica Hema 580. For comparison of the Atellica Hema 580 with the Sysmex XN-1000 (Sysmex, Kobe, Japan), 140 samples from adult and pediatric patients including both normal and abnormal hematology profiles were analyzed in parallel. RESULTS: The Atellica Hema 580 demonstrated acceptable imprecision within the manufacturer's specifications for whole blood and body fluid modes, good linearity for high and low ranges and no significant carryover. The full blood count, differential and reticulocyte correlated well with the Sysmex XN-1000, except for mean cell hemoglobin concentration, basophil and large immature cells. The optical platelet count, reflexed in 34 samples with a platelet count <150 × 109 /l, showed a strong correlation with the fluorescent platelet count on the Sysmex XN-1000. The morphology flagging efficiency was 92% for white blood cells, 95% for red blood cells and 87% for platelets. CONCLUSION: The Atellica Hema 580 showed good analytical performance and workflow efficiency for a wide range of patient samples.


Assuntos
Hematologia , Adulto , Humanos , Criança , Contagem de Células Sanguíneas/métodos , Hematologia/métodos , Contagem de Plaquetas/métodos , Leucócitos , Plaquetas , Reprodutibilidade dos Testes
10.
Einstein (Sao Paulo) ; 21: eAO0501, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38126661

RESUMO

OBJECTIVE: This study aimed to compare the hematological parameters released by hematological analyzers with those released in customer reports. METHODS: We conducted a descriptive study in the laboratories of a medium-sized municipality in the state of Minas Gerais registered in the National Register of Health Establishments. Interviews were conducted using a questionnaire to obtain information regarding the parameters released by the analyzers and those available in the customer's report. RESULTS: Sixteen laboratories were evaluated, and none of them released all the parameters obtained from the hematological analyzers to customers. The red blood cell distribution width was released in 88% of the laboratories, atypical lymphocytes in 70%, mean platelet volume in 50%, platelet distribution width and platelet count in 20%. No laboratory released information on reticulocytes, fraction of immature reticulocytes and immature granulocytes, nucleated erythrocyte count, immature platelet fraction and reticulocyte hemoglobin, and large platelet rate. CONCLUSION: All evaluated clinical analysis laboratories had at least one parameter that was not released in the customer's report despite being released by the hematological analyzers. The lack of knowledge on the part of professionals about the clinical importance of each parameter of the complete blood count results in a loss in patient assessment, and it is important to include these parameters in the complete blood count report.


Assuntos
Plaquetas , Índices de Eritrócitos , Humanos , Contagem de Células Sanguíneas/métodos , Contagem de Eritrócitos/métodos , Contagem de Plaquetas/métodos
11.
Int J Lab Hematol ; 45(5): 691-699, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37338111

RESUMO

INTRODUCTION: The manual differential count has been recognized for its disadvantages, including large interobserver variability and labor intensiveness. In this light, automated digital cell morphology analyzers have been increasingly adopted in hematology laboratories for their robustness and convenience. This study aims to evaluate the white blood cell differential performance of the Mindray MC-80, the new automated digital cell morphology analyzer. METHODS: The cell identification performance of Mindray MC-80 was evaluated for sensitivity and specificity using pre-classification and post-classification of each cell class. The method comparison study used manual differentials as the gold standard for calculating Pearson correlation, Passing-Bablok regression, and Bland-Altman analysis. In addition, the precision study was performed and evaluated. RESULTS: The precision was within the acceptable limit for all cell classes. Overall, the specificity of cell identification was higher than 95% for all cell classes. The sensitivity was greater for 95% for most cell classes, except for myelocytes (94.9%), metamyelocytes (90.9%), reactive lymphocytes (89.7%), and plasma cells (60%). Pre-classification and post-classification results correlated well with the manual differential results for all the cell types investigated. The regression coefficients were greater than 0.9 for most cell classes except for promyelocytes, metamyelocytes, basophils, and reactive lymphocytes. CONCLUSION: The performance of Mindray MC-80 for white blood cell differentials is reliable and seems to be acceptable even in abnormal samples. However, the sensitivity is less than 95% for certain abnormal cell types, so the user should be aware of this limitation where such cells are suspected.


Assuntos
Hematologia , Leucócitos , Humanos , Contagem de Leucócitos , Reprodutibilidade dos Testes , Contagem de Células Sanguíneas/métodos , Hematologia/métodos , Plasmócitos
12.
Int J Lab Hematol ; 45(5): 659-667, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37128804

RESUMO

INTRODUCTION: This study assessed the comparability of complete blood count (CBC) parameters between capillary and venous samples, and extended previous research by examining the influence of different storage temperatures on CBC stability up to 7 days after sample collection. METHODS: Venous and capillary blood samples were collected from 93 adult patients. Hemoglobin (Hb), hematocrit (Ht), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), mean platelet volume (MPV), leukocytes, lymphocytes, basophils, eosinophils, erythrocytes, red cell distribution width (RDW), immature granulocytes (IG), immature reticulocyte fraction (IRF), monocytes, neutrophils, platelets, and reticulocytes were measured. Deming regression and mean relative differences between venous and capillary measurements were contrasted with desirable total allowable error (TEa). Stability was assessed in 20-27 venous blood samples stored at 4, 21-22, or 30°C, and analyzed at 0, 24, 48, 72, 96, 120, 144, and 168 h. Mean relative change with respect to baseline measurements was compared to the desirable TEa to determine acceptable stability. RESULTS: Deming regression demonstrated strong linear correlations and acceptable variation between venous and capillary measurements. Erythrocytes, Hb, Ht, MCH, MCV, RDW, reticulocytes, and platelets showed acceptable stability for at least 96 h at 4°C. Mean relative change exceeded desirable TEa after 24 h at 30°C for all parameters, except erythrocytes, Hb, leukocytes, and MCH. CONCLUSION: Clinical laboratory specialists and clinicians should be aware of potential differences between venous and capillary measurements, and the influence of storage conditions. Clinical validity of delayed CBC analysis depends on the clinical situation and required precision of the result.


Assuntos
Índices de Eritrócitos , Eritrócitos , Adulto , Humanos , Contagem de Células Sanguíneas/métodos , Hematócrito , Eritrócitos/química , Hemoglobinas/análise , Eosinófilos
13.
Ann Lab Med ; 43(5): 418-424, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37080742

RESUMO

Background: Delta checks increase patient safety by identifying automated hematology analyzer errors. International standards and guidelines for the complete blood count (CBC) delta check method have not been established. We established an effective, practical CBC delta check method and criteria. Methods: We assessed five delta check methods for nine CBC items (Hb, mean corpuscular volume, platelet count, white blood cell [WBC] count, and five-part WBC differential counts) using 219,804 blood samples from outpatients and inpatients collected over nine months. We adopted the best method and criteria and evaluated them using 42,652 CBC samples collected over two weeks with a new workflow algorithm for identifying test errors and corrections for Hb and platelet count. Results: The median delta check time interval was 1 and 21 days for inpatients and outpatients (range, 1-20 and 1-222 days), respectively. We used delta values at 99.5% as delta check criteria; the criteria varied among the five methods and between outpatients and inpatients. The delta percent change (DPC)/reference range (RR) rate performed best as the delta check for CBC items. Using the new DPC/RR rate method, 1.7% of total test results exceeded the delta check criteria; the retesting and resampling rates were 0.5% and 0.001%, respectively. Conclusions: We developed an effective, practical delta check method, including RRs and delta check time intervals, and delta check criteria for nine CBC items. The criteria differ between outpatients and inpatients. Using the new workflow algorithm, we can identify the causes of criterion exceedance and report correct test results.


Assuntos
Hematologia , Humanos , Contagem de Células Sanguíneas/métodos , Contagem de Leucócitos , Contagem de Plaquetas , Controle de Qualidade , Hematologia/métodos
14.
Transfus Med ; 33(3): 221-226, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36861470

RESUMO

BACKGROUND AND OBJECTIVES: Lifeblood completes full blood count samples for selected donors to assess their suitability for future donations. Removing the current practice for refrigerated (2-8°C) storage and aligning with room temperature (20-24°C) storage of other donor blood samples would produce significant efficiencies in blood donor centres. This study aimed to compare full blood count results under two temperature conditions. MATERIALS AND METHODS: Paired full blood count samples were collected from 250 whole blood or plasma donors. These were stored either refrigerated or room temperature for testing on arrival at the processing centre and the following day. The primary outcomes of interest included differences between mean cell volume, haematocrit, platelet count, white cell and differential counts, and the need to produce blood films, based on existing Lifeblood criteria. RESULTS: A statistically significant (p < 0.05) difference for most full blood count parameters results was found between the two temperature conditions. The number of blood films required was similar under each temperature condition. CONCLUSION: The clinical significance of the small numerical differences in results is considered minimal. Furthermore, the number of blood films required remained similar under either temperature condition. Given the significant reductions in time, processing and costs associated with room temperature over refrigerated processing, we recommend a further pilot study to monitor the broader impacts, with the intent to implement national storage of full blood count samples at room temperature within Lifeblood.


Assuntos
Temperatura , Humanos , Projetos Piloto , Contagem de Células Sanguíneas/métodos , Hematócrito , Contagem de Plaquetas
15.
Analyst ; 148(9): 2021-2034, 2023 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-36970954

RESUMO

Blood analysis through complete blood count is the most basic medical test for disease diagnosis. Conventional blood analysis requires bulky and expensive laboratory facilities and skilled technicians, limiting the universal medical use of blood analysis outside well-equipped laboratory environments. Here, we propose a multiparameter mobile blood analyzer combined with label-free contrast-enhanced defocusing imaging (CEDI) and machine vision for instant and on-site diagnostic applications. We designed a low-cost and high-resolution miniature microscope (size: 105 mm × 77 mm × 64 mm, weight: 314 g) that comprises a pair of miniature aspheric lenses and a 415 nm LED for blood image acquisition. The analyzer, adopting CEDI, can obtain both the refractive index distributions of the white blood cell (WBC) and hemoglobin spectrophotometric information, enabling the analyzer to supply rich blood parameters, including the five-part WBC differential count, red blood cell (RBC) count, and mean corpuscular hemoglobin (MCH) quantification with machine vision algorithms and the Lambert-Beer law. We have shown that our assay can analyze a blood sample within 10 minutes without complex staining, and measurements (30 samples) from the analyzer have a strong linear correlation with clinical reference values (significance level of 0.0001). This study provides a miniature, light weight, low-cost, and easy-to-use blood analysis technique that overcomes the challenge of simultaneously realizing FWD count, RBC count, and MCH analysis using a mobile device and has great potential for integrated surveillance of various epidemic diseases, including coronavirus infection, invermination, and anemia, especially in low- and middle-income countries.


Assuntos
Testes Hematológicos , Hemoglobinas , Contagem de Células Sanguíneas/métodos , Testes Hematológicos/métodos , Contagem de Eritrócitos/métodos , Contagem de Leucócitos , Hemoglobinas/análise
16.
J Cosmet Dermatol ; 22(7): 2099-2104, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36757679

RESUMO

OBJECTIVE: To compare complete blood count (CBC) parameters and inflammatory factors in the patients with different grade of acne vulgaris and healthy controls. METHODS: A total of 20 patients were enrolled in this study. Patients were divided into mild group and moderate-to-severe group based on the acne severity, and compared to controls. Inflammatory factors (TNF-α, IL-6, IL-8, and IL1-α) detected by ELISA and complete blood count parameters (MPV, NLR, dNLR, PLR, LMR, and SII) obtained by routine blood tests were compared among the three group. RESULTS: All CBC parameters were not significantly elevated in patients with acne compared to healthy controls. However, the present studies have found that the inflammatory factors in acne patients were significantly elevated relative to healthy controls, and increase with the acne grade. CONCLUSIONS: Inflammatory factors are convenient parameters to show inflammatory response to acne vulgaris, and may be a new clinical method for judging the acne grades of objectively. Considering the use of antibiotic, we believe that this metric worth further study.


Assuntos
Acne Vulgar , Humanos , Estudos Retrospectivos , Contagem de Células Sanguíneas/métodos , Acne Vulgar/tratamento farmacológico , Inflamação
17.
Scand J Clin Lab Invest ; 83(1): 31-37, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36622319

RESUMO

Due to technological advancements, haematology analysers are becoming increasingly more complex. Before introducing new analyzers, laboratories must compare the agreement between the new and the old instruments. This study aimed to quantify the method agreement between Sysmex XT-4000i and Alinity hq analysers in order to establish whether they can be used interchangeably. A total of 415 complete blood counts (CBC) from adult patients of the Emergency Clinical County Hospital of Târgu Mureș, Romania, were analysed within 4 h from the collection on Sysmex XT-4000i (considered the reference method), then on Alinity hq. Statistical analysis consisted of outlier removal, Spearman Correlation, Bland-Altman test, and Passing-Bablok regression. For each CBC parameter, the analytical difference between methods was compared with the Reference Change Value (RCV) at medical decision levels (MDL). Despite using different technologies, the instruments have a good agreement regarding cell differentiation and counting. Cell counting and haemoglobin measurement showed a good agreement at all (Medical Decision Limits) MDLs. The analytical difference between methods surpassed the (Reference Change Value) RCV with 1.2% at the 14% MDL of HCT and with 0.2% at the 100 fL MDL of MCV. This study can not tell whether Sysmex or Alinity is superior, only if the two methods agree. The poorer agreement observed for RBC indices, especially MCHC, suggests an accumulation of differences caused by the different working principles of the two methods. However, it is reasonable to assume that such small differences will not affect clinical decision-making and patient outcome.


Assuntos
Hematologia , Laboratórios , Adulto , Humanos , Reprodutibilidade dos Testes , Contagem de Células Sanguíneas/métodos , Valores de Referência
18.
Clin Chem Lab Med ; 61(6): 1116-1122, 2023 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-36669090

RESUMO

OBJECTIVES: Establishing direct reference intervals for pediatric patients is a costly, challenging, and time-consuming enterprise. Indirectly established reference intervals can help to ameliorate this situation. It was our objective to establish population-specific reference intervals for automated white blood cell differentials via data mining and non-parametric percentile method. METHODS: Blood counts and automated white blood cell differentials of patients aged 0 days to 18 years, performed from the 1st of January 2018 until the 30th of June 2022, were identified in our laboratory information system. Reference intervals were established in accordance with IFCC and CLSI recommendations as well as the propositions by Haeckel et al. RESULTS: Initially, 47,173 blood counts on our SYSMEX XN-9000 were identified. 11,707 data sets were excluded, leaving 35,466 sample sets for analysis. Of these, 17,616 contained automated white blood cell differentials. Due to insufficient patient numbers, no reference intervals for automated white blood cell differentials could be established for children aged <7 months. In comparison to the corresponding reference intervals published by Herklotz et al., reference intervals determined by us showed relevant differences throughout all age groups. CONCLUSIONS: The combination of non-parametric percentile method and the propositions by Haeckel et al. utilizing conscientious data mining appears to be potent alternative to direct reference interval determination.


Assuntos
Leucócitos , Humanos , Criança , Berlim , Valores de Referência , Contagem de Células Sanguíneas/métodos
19.
Infect Dis (Lond) ; 55(4): 299-302, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36718519

RESUMO

BACKGROUND: A rare case of coinfection of Plasmodium falciparum and SARS-CoV-2 disease in Croatia is presented in this report. METHODS: We tracked epidemiological and laboratory findings in a patient with SARS-CoV-2 and Plasmodium falciparum coinfection. A complete blood count was performed using the Sysmex XN-2000 analyser (Sysmex Corporation, Kobe, Japan), coagulation analyses were performed using the BCS XP coagulometer (Siemens Healthineers AG, Erlangen, Germany). Procalcitonin (PCT) and Interleukin-6 (IL-6) were measured by electrochemiluminescence immunoassay (ECLIA) using the Cobas e411 (Roche Diagnostics GmbH, Mannheim, Germany) analyser and high sensitivity troponin I (hsTnI) was measured using the Dimension EXL with LM analyser (Siemens Healthcare Diagnostics, Newark, USA). All other biochemistry analyses were performed using the Olympus AU680 (Beckman Coulter, Brea, California, USA) analyser. White blood cell differential analysis has been performed by examining the blood smear using the CellaVision DM1200 (CellaVision AB, Lund, Sweden) automatic analyser. RESULTS: Even though the patient's initial health condition was disturbed, as a result of the physician's comprehensive anamnesis accompanied by laboratory findings, prompt diagnosis and appropriate therapy were assured, and consequently, the patient recovered. CONCLUSION: In a pandemic, testing each febrile patient for the SARS-CoV-2 virus is of essential importance. However, the possibility of coinfection with another infectious disease agent cannot be disregarded.


Assuntos
COVID-19 , Coinfecção , Humanos , Plasmodium falciparum , SARS-CoV-2 , Coinfecção/diagnóstico , COVID-19/diagnóstico , Contagem de Células Sanguíneas/métodos
20.
Vet Clin North Am Small Anim Pract ; 53(1): 29-52, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36400473

RESUMO

An automated complete blood count (CBC), although quick and relatively effortless, is limited in its diagnostic usefulness because results can be affected by misclassification of cellular and noncellular components and abnormal cellular morphology. Microscopic evaluation of a blood smear allows for quality control of automated CBC results as well as identification of cellular morphology that cannot be detected by automated hematology analyzers, and its importance should not be overlooked, especially in clinically ill patients.


Assuntos
Contagem de Células Sanguíneas , Animais , Contagem de Células Sanguíneas/veterinária , Contagem de Células Sanguíneas/métodos